E07 — Motor Control / Electronic Fault
E07 is not in Bosch's official US dryer error-code list (which only documents E01/E02 as a pair, E06, and an E08/E09/E24/E25/E28/E90 electronics group — note that E09 is documented as a generic 'electronics fault,' not specifically a compressor fault). The 'motor control / electronic fault' explanation below is not confirmed on Bosch's US consumer page — verify against your model's manual.
- Keep using it?
- Limited use only
- DIY difficulty
- Hard
- Verified against
- bosch-home.com ↗
How to fix it
- Unplug the dryer and allow 10 minutes for capacitors to discharge.
- Remove the kickplate and inspect the evaporator/condenser fins behind the condenser unit — vacuum gently with a soft brush.
- Verify the condenser unit and lint filters are clean.
- Listen at startup — humming with no compressor run suggests capacitor or start relay failure.
- Test the compressor start capacitor with a meter; replace if out of spec.
- If refrigerant leak is suspected (oily residue, no cooling at evaporator), call a certified appliance tech — sealed system work is not DIY.
- If compressor windings test open or shorted, schedule a service call — heat-pump compressor replacement is professional-only.
- Document model and serial before contacting Bosch service — many heat-pump dryers have extended sealed-system warranties.
Why it happens
Typical signs: No heat on heat-pump model · Clothes cold at end of long cycle · Clicking sound from base of dryer · Cycle ends prematurely
- Compressor start capacitor failed Compressor hums but can't start; capacitor is a common wear item.
- Compressor overload tripped Internal klixon trips on overcurrent — often due to refrigerant or ventilation issues.
- Refrigerant leak in sealed system Loss of refrigerant — requires sealed-system repair by certified tech.
- Restricted airflow over evaporator/condenser Dust/lint buildup on heat-exchange fins causes high-pressure trip.
- Failed inverter or compressor relay on control board Electronics that drive the compressor have failed.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Bosch heat pump dryer start capacitor Common replacementAmazon →
More Bosch dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: bosch-home.com.