F92 — Maximum Door-Open Time Exceeded
F92 is part of the Frigidaire F90-F94 door-lock family and indicates the maximum oven door-OPEN time was exceeded (the door stayed open too long, or the door light switch is misreading). It is not a latch-locked-vs-unlocked mismatch (those are F90/F91/F93/F94). Check the door switch and latch.
- Keep using it?
- Limited use only
- DIY difficulty
- Hard
- Verified against
- frigidaire.com ↗
How to fix it
- Power off.
- Remove the top panel and inspect the latch — manually move it to the unlocked position.
- Test each microswitch with a meter for proper open/close as the cam moves.
- Replace the door lock assembly if any switch fails the test.
- Reroute or repair any chafed harness wiring near the latch.
Why it happens
Typical signs: F92 at idle, not during cleaning · Oven won't bake or broil · Door reports locked when it's clearly open
- Stuck or shorted lock microswitch Contacts welded closed or actuator tab bent.
- Broken latch cam Cam jammed in the lock position.
- Pinched harness shorting the switch wire Wire grounded against sheet metal.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Frigidaire oven door lock assembly Common replacementAmazon →
More Frigidaire oven codes