H1 — Fresh Food Thermistor Open
Main board reads an open circuit on the fresh-food (refrigerator) section thermistor. Without a valid temp reading, cooling control is degraded.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- frigidaire.com ↗
How to fix it
- Unplug the refrigerator.
- Locate fresh food thermistor (typically clipped near the top of the fresh food compartment).
- Disconnect and measure resistance with a multimeter — should be roughly 16k ohms at 32 deg F (verify with tech sheet).
- If reading is infinite (open), replace the thermistor.
- If sensor is good, inspect wiring back to the main board for breaks.
- If wiring is good, replace the main control board.
Why it happens
Typical signs: H1 on display · Fresh food too cold or too warm · Compressor cycles abnormally · Cannot adjust fridge temperature
- Failed fresh food thermistor Internal element opens with age.
- Broken or pinched thermistor wire Often near the back wall or evaporator drain area.
- Disconnected thermistor harness Loose at the main board or sensor end.
- Main control board input failure Sensor input on the board is damaged.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Fresh food thermistor Common replacementAmazon →
More Frigidaire refrigerator codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: frigidaire.com.