KitchenAid · Dryer Moderate
E2 — Thermistor Shorted
Companion to E1 — the thermistor is reading shorted. The control reads excessively high temperature and aborts heat.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- kitchenaid.com ↗
How to fix it
- Unplug the dryer.
- Inspect the thermistor wiring for any pinch or short to ground.
- Test thermistor resistance — replace if near 0Ω.
- Repair wiring and reassemble.
- Replace the ACU only if sensor and wiring test good.
Why it happens
Typical signs: E2 displayed · No heat · Cycle stops
- Shorted thermistor Internal short
- Wire grounded against sheet metal Chafed wire shorting to chassis
- Damaged ACU input Board-side failure (rare)
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Dryer thermistor Common replacementAmazon →
More KitchenAid dryer codes