KitchenAid · Dryer Moderate

E2 — Thermistor Shorted

Companion to E1 — the thermistor is reading shorted. The control reads excessively high temperature and aborts heat.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
kitchenaid.com ↗

How to fix it

  1. Unplug the dryer.
  2. Inspect the thermistor wiring for any pinch or short to ground.
  3. Test thermistor resistance — replace if near 0Ω.
  4. Repair wiring and reassemble.
  5. Replace the ACU only if sensor and wiring test good.

Why it happens

Typical signs: E2 displayed · No heat · Cycle stops

  • Shorted thermistor Internal short
  • Wire grounded against sheet metal Chafed wire shorting to chassis
  • Damaged ACU input Board-side failure (rare)

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

More KitchenAid dryer codes

All KitchenAid codes → All dryer codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: kitchenaid.com.