67 — Door open / not fully closed
The board detected the door open (or a gap large enough that the switch reads open) for longer than the alarm threshold — typically 5+ minutes. The code is a warning, not a sealed-system fault.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Easy
- Verified against
- lg.com ↗
How to fix it
- Open and reclose each door firmly — confirm the alarm stops.
- Inspect for items blocking full close (gallon jugs, tall bottles, in-door bins).
- Inspect the gasket for tears or compression dents; warm it with a hair dryer to reshape if mildly deformed.
- Press each door switch by hand and listen — interior light should turn off.
- Use a level: tilt the unit slightly back via the front leveling feet so doors swing closed.
- If the switch is stuck or unresponsive, replace it.
Why it happens
Typical signs: 67 on display · Door alarm beeping · Interior light may stay on · Higher than normal temperatures if persistent
- Door physically ajar Item on a shelf or in a bin blocks full close.
- Worn/deformed gasket Gasket no longer seats — gap stays open.
- Failed door switch Plunger switch stuck open or electrically failed.
- Misaligned door / sagging hinge Door drooped — gasket misses the cabinet.
- Not leveled Unit tilted forward causes doors to swing open.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More LG refrigerator codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: lg.com.