Maytag · Oven Serious

F3E2 — Oven Over-Temperature

The cavity temperature exceeded the safe upper limit for the active mode. Heating is shut off as a safety lockout.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
maytag.com ↗

How to fix it

  1. Cut power immediately at the breaker.
  2. Allow the oven to fully cool (2+ hours).
  3. Restore power and attempt a low-temp bake while watching cavity temp.
  4. If the element stays on past setpoint, the EOC relay is welded — replace the EOC.
  5. If sensor readings are off, replace the temperature sensor.

Why it happens

Typical signs: F3E2 shown after extended bake or broil · Strong heat / smoke from oven · Oven will not restart until cooled

  • Stuck-closed bake or broil relay A welded relay on the EOC keeps an element energized.
  • Failed temperature sensor reading low Sensor is drifting and not reporting true cavity temperature.
  • Door latch stuck during self-clean Mechanical issue trapped clean-cycle heat.