Maytag · Oven Moderate

F5E0 — Door Switch Fault

The control sees a door switch state that does not match the door latch position. Often shows up around self-clean attempts.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
maytag.com ↗

How to fix it

  1. Open and close the door firmly and try a bake cycle.
  2. Disconnect power and remove the rear access panel.
  3. Locate the door switch and test continuity in both door states.
  4. Replace the door switch if it does not change state.
  5. Inspect door hinges for sag and adjust or replace if needed.

Why it happens

Typical signs: F5E0 displayed · Self-clean will not start · Oven light behavior is wrong relative to door state

  • Failed door switch The plunger or microswitch on the door is not opening/closing the circuit correctly.
  • Misaligned door Door hinges have sagged and the switch is not actuated fully.
  • Wiring harness fault Open or short in door switch wiring to the EOC.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.