F6E0 — Loss of Communication

The user interface board and the main control are not communicating. The control cannot accept input from the touch panel.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
maytag.com ↗

How to fix it

  1. Cut power for 5 minutes.
  2. Pull the oven and remove the rear/top access panel.
  3. Reseat the harness between the user interface and the main control board.
  4. Restore power and try a cycle.
  5. If F6E0 returns, swap the user interface board first; replace the main control if it persists.

Why it happens

Typical signs: F6E0 on display · Touchpad unresponsive · Oven will not start any cycle

  • Loose ribbon / harness between UI and main control Connector backed out or pin not seated.
  • Failed user interface board UI board has lost its communication interface.
  • Failed main control board Main control communication port has failed.