F6E0 — Loss of Communication
The user interface board and the main control are not communicating. The control cannot accept input from the touch panel.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- maytag.com ↗
How to fix it
- Cut power for 5 minutes.
- Pull the oven and remove the rear/top access panel.
- Reseat the harness between the user interface and the main control board.
- Restore power and try a cycle.
- If F6E0 returns, swap the user interface board first; replace the main control if it persists.
Why it happens
Typical signs: F6E0 on display · Touchpad unresponsive · Oven will not start any cycle
- Loose ribbon / harness between UI and main control Connector backed out or pin not seated.
- Failed user interface board UI board has lost its communication interface.
- Failed main control board Main control communication port has failed.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Oven user interface (UI) board Common replacementAmazon →
More Maytag oven codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: maytag.com.