E012 — False Flame / Flame Loss
The control board sees a flame signal when the gas valve is commanded off, or loses the flame signal mid-burn. The unit shuts down for safety.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- navieninc.com ↗
How to fix it
- Power-cycle the unit and observe whether the code returns on the next call for heat.
- Remove and clean the flame rod with emery cloth; reseat firmly.
- Inspect ceramic insulator for hairline cracks — replace rod if cracked.
- Check and tighten the burner ground screw and chassis ground.
- Verify gas pressure stays in spec under full fire.
- Inspect intake and exhaust terminations for short-circuiting or blockage.
- If the code persists with a clean rod, good ground, and correct gas pressure, replace the PCB.
Why it happens
Typical signs: Unit shuts off mid-shower · Brief hot water then cold · E012 displayed · Cycling on and off
- Contaminated flame rod Carbon, soot or scale on the rod gives a false or unstable signal.
- Poor ground at the burner assembly Flame rectification needs a solid earth ground — corroded burner ground strap or loose chassis ground.
- Cracked flame rod ceramic Allows leakage current to ground, mimicking a flame.
- Low or fluctuating gas pressure Pressure dip during firing causes flame to detach from the rod.
- Recirculation of flue gases Improperly terminated or restricted vent pulls combustion products back across the rod.
- Failed PCB Flame amplifier circuit on the main board reading incorrectly.