Maytag · Microwave Moderate

F2E2 — User Interface Mismatch

The user interface board reports a part number or configuration that doesn't match what the main control board expects.

Keep using it?
Yes, with caution
DIY difficulty
Easy
Verified against
maytag.com ↗

How to fix it

  1. Verify the part numbers of the installed UI and ACU against the model's tech sheet.
  2. Order the correct part number if a mismatch is confirmed.
  3. If both boards are genuine and correct, unplug for 5 minutes and retry.
  4. If F2E2 persists with verified-correct parts, replace the user interface board.
  5. If still failing, replace the main control board.

Why it happens

Typical signs: F2E2 at power-up · Microwave inoperative · Common after a board replacement

  • Wrong replacement UI board installed Incorrect part number ordered or substituted.
  • Mismatched ACU after replacement New main control not paired correctly with existing UI.
  • Failed user interface board UI corrupted and reporting wrong identity.

More Maytag microwave codes

All Maytag codes → All microwave codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: maytag.com.