Maytag · Microwave Moderate
F2E2 — User Interface Mismatch
The user interface board reports a part number or configuration that doesn't match what the main control board expects.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Easy
- Verified against
- maytag.com ↗
How to fix it
- Verify the part numbers of the installed UI and ACU against the model's tech sheet.
- Order the correct part number if a mismatch is confirmed.
- If both boards are genuine and correct, unplug for 5 minutes and retry.
- If F2E2 persists with verified-correct parts, replace the user interface board.
- If still failing, replace the main control board.
Why it happens
Typical signs: F2E2 at power-up · Microwave inoperative · Common after a board replacement
- Wrong replacement UI board installed Incorrect part number ordered or substituted.
- Mismatched ACU after replacement New main control not paired correctly with existing UI.
- Failed user interface board UI corrupted and reporting wrong identity.
More Maytag microwave codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: maytag.com.