E432 — Cold Water Inlet 2 Thermistor Fault
The cold water inlet 2 thermistor — the temperature sensor on the second cold-water inlet connection found on units set up with two inlets — is open, shorted, or reading outside its expected resistance range.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- navieninc.com ↗
How to fix it
- Power off the unit.
- Locate the cold water inlet 2 thermistor and reseat its connector.
- Measure resistance and compare to the manufacturer's spec chart for the measured water temperature.
- Replace the thermistor if the reading is open, shorted, or out of range.
- Inspect harness routing for pinches or chafing.
Why it happens
Typical signs: E432 on display · Inlet temperature reading looks wrong or erratic on units with a second cold-water inlet connection · Unit shuts down on a call for heat
- Failed thermistor Element open or shorted.
- Loose or corroded connector Bad contact at the sensor or PCB header.
- Wiring damage Pinched or chafed harness between the sensor and the board.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Navien inlet thermistor Common replacementAmazon →
More Navien tankless water heater codes
Frequently asked questions
What does the E432 code mean on a Navien tankless water heater?
The cold water inlet 2 thermistor — the temperature sensor on the second cold-water inlet connection found on units set up with two inlets — is open, shorted, or reading outside its expected resistance range.
What causes the E432 code on a Navien tankless water heater?
Failed thermistor: Element open or shorted. Loose or corroded connector: Bad contact at the sensor or PCB header. Wiring damage: Pinched or chafed harness between the sensor and the board.
Is it safe to keep using a Navien tankless water heater with a E432 error?
Yes, with caution. This is rated a moderate-severity fault.
How do I fix E432 on a Navien tankless water heater?
Power off the unit. Locate the cold water inlet 2 thermistor and reseat its connector. Measure resistance and compare to the manufacturer's spec chart for the measured water temperature.
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: navieninc.com.