E594 — Gas Valve / Modulation Fault
The gas valve modulation feedback does not match the commanded firing rate — valve coil resistance or position is out of spec.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- navieninc.com ↗
How to fix it
- Power off; reseat the gas valve connector.
- Measure coil resistance per service-manual spec; replace gas valve if out of range.
- If valve coil tests good, replace the PCB.
- After any gas valve work, verify manifold pressure and combustion with a combustion analyzer.
Why it happens
Typical signs: E594 on display · Unit will not fire · Inconsistent flame · Burner over- or under-firing
- Failed gas valve coil Modulation winding open or shorted.
- Loose wiring at gas valve Connector partially seated.
- PCB driver failure Board not driving the valve correctly.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Navien gas valve Common replacementAmazon →
More Navien tankless water heater codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: navieninc.com.