Whirlpool Dishwasher F6E2 — Water Inlet Valve Electrical Failure
Whirlpool Dishwasher · Error code F6E2
What F6E2 Means
The control detects an open circuit or shorted solenoid on the water inlet valve.
Symptoms
- F6E2 on display
- No fill or partial fill
- Cycle aborts at fill phase
Common Causes
Open or shorted coil — resistance should read ~1,400 ohms.
Connector at the valve has backed off or corroded.
Less common; rule out the valve first.
How to Fix It
- Power off at the breaker and shut off the water supply.
- Pull the toe-kick and locate the inlet valve at the bottom-left front of the dishwasher.
- Unplug the valve and measure resistance across its terminals — replace if not in the ~1,400 ohm range.
- Inspect the wire connectors for corrosion and reseat firmly.
- If the valve tests good, replace the control board.
Parts You May Need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More Whirlpool Dishwasher Codes
Verified against manufacturer documentation: applianceaid.com