Amana · Dryer Moderate

Ed — End of cycle / drying complete indication issue

On some models Ed indicates the cycle finished but the sensor moisture reading suggests the load is still damp — auto-cycle ended prematurely.

Keep using it?
Yes, with caution
DIY difficulty
Easy
Verified against
amana.com ↗

How to fix it

  1. Open the door and clean the two metal moisture sensor strips with rubbing alcohol.
  2. Stop using fabric softener sheets in the dryer (they leave residue).
  3. For very small loads, use timed dry instead of sensor cycles.
  4. Clean the lint screen and inspect the exhaust vent.
  5. Run a test sensor cycle to verify Ed clears.

Why it happens

Typical signs: Ed shown at end of cycle · Clothes still damp · Short auto-dry cycles

  • Coated moisture sensor bars Fabric softener residue insulating the bars — most common cause.
  • Small load with sensor Load too small to consistently touch the moisture bars.
  • Restricted airflow Clogged vent causing early thermal shutdown.

More Amana dryer codes

All Amana codes → All dryer codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: amana.com.