F22 — Outlet Thermistor Fault
Exhaust thermistor (outlet temperature sensor) is reading out of range — either open circuit or shorted. The control cannot regulate drying temperature.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- amana.com ↗
How to fix it
- Unplug the dryer.
- Access the blower housing (usually behind the back panel) to find the thermistor.
- Clean lint off the thermistor body with a soft brush.
- Measure thermistor resistance with a multimeter — should be ~10kΩ at 70°F.
- Check continuity of the wires from the thermistor to the main control.
- Replace the thermistor if resistance is out of spec or open.
Why it happens
Typical signs: F22 on display · Dryer stops mid-cycle · Clothes over- or under-dried · Sensor cycles end prematurely
- Failed outlet thermistor Resistance out of spec — typically should read ~10kΩ at room temp.
- Lint-coated thermistor Heavy lint coating insulates the sensor from airflow.
- Wiring open to thermistor Broken wire or unseated connector at the thermistor.
- Failed main control Less common — ACU input circuit failure.