Amana · Dryer Moderate

F28 — Communication Error (UI to Main)

The User Interface board cannot communicate with the Main Control board. Dryer may not respond to inputs.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
amana.com ↗

How to fix it

  1. Unplug the dryer for 5 minutes.
  2. Open the control console and inspect the harness between UI and main control.
  3. Reseat both ends of the connector.
  4. Inspect the harness for damage along its full run.
  5. Replace UI board first if reseat doesn't fix; if F28 persists, replace main control.

Why it happens

Typical signs: F28 displayed · Display freezes · Buttons do nothing · Beeps with no action

  • Loose harness between UI and ACU Ribbon or connector at one end worked loose.
  • Failed UI board UI lost its communication chip.
  • Failed main control board ACU comm circuit failed.
  • Damaged harness Pinched or chafed wires between boards.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • User interface control board Common replacement