PF — Power Failure
Power Failure code indicates the dryer lost power during a cycle. The control board detected an unexpected interruption to the incoming AC power.
- Keep using it?
- Yes — fix when convenient
- DIY difficulty
- Easy
- Verified against
- amana.com ↗
How to fix it
- Press Start to resume the cycle or Cancel to clear the code.
- Check the home breaker for the dryer — reset fully off then on.
- Inspect the power cord at the back of the dryer; tighten the three terminal screws after unplugging.
- Check the outlet with a multimeter for steady 240V (L1-L2) and 120V on each leg to neutral.
- If PF appears with no outage occurring, replace the main electronic control board.
Why it happens
Typical signs: PF flashes on display after a power outage · Cycle stopped mid-run · Dryer beeps until acknowledged
- Brief power outage or brownout Most common cause — utility blip or breaker trip interrupted the cycle.
- Loose power cord connection Cord terminals at the dryer block or outlet not fully seated, especially after install or move.
- Tripped or weak breaker 240V breaker partially tripped — one leg dropped out momentarily.
- Failed control board If PF recurs with no actual outage, the main control may be misreading line voltage.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More Amana dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: amana.com.