Amana · Dryer Minor

PF — Power Failure

Power Failure code indicates the dryer lost power during a cycle. The control board detected an unexpected interruption to the incoming AC power.

Keep using it?
Yes — fix when convenient
DIY difficulty
Easy
Verified against
producthelp.amana.com ↗

How to fix it

  1. Press Start to resume the cycle or Cancel to clear the code.
  2. Check the home breaker for the dryer — reset fully off then on.
  3. Inspect the power cord at the back of the dryer; tighten the three terminal screws after unplugging.
  4. Check the outlet with a multimeter for steady 240V (L1-L2) and 120V on each leg to neutral.
  5. If PF appears with no outage occurring, replace the main electronic control board.

Why it happens

Typical signs: PF flashes on display after a power outage · Cycle stopped mid-run · Dryer beeps until acknowledged

  • Brief power outage or brownout Most common cause — utility blip or breaker trip interrupted the cycle.
  • Loose power cord connection Cord terminals at the dryer block or outlet not fully seated, especially after install or move.
  • Tripped or weak breaker 240V breaker partially tripped — one leg dropped out momentarily.
  • Failed control board If PF recurs with no actual outage, the main control may be misreading line voltage.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • Dryer power cord 4-prong 30A Common replacement
    Amazon →
  • Main electronic control board Common replacement
    Amazon →

More Amana dryer codes

All Amana codes → All dryer codes →

Frequently asked questions

What does the PF code mean on a Amana dryer?

Power Failure code indicates the dryer lost power during a cycle. The control board detected an unexpected interruption to the incoming AC power.

What causes the PF code on a Amana dryer?

Brief power outage or brownout: Most common cause — utility blip or breaker trip interrupted the cycle. Loose power cord connection: Cord terminals at the dryer block or outlet not fully seated, especially after install or move. Tripped or weak breaker: 240V breaker partially tripped — one leg dropped out momentarily.

Is it safe to keep using a Amana dryer with a PF error?

Yes — fix when convenient. This is rated a minor-severity fault.

How do I fix PF on a Amana dryer?

Press Start to resume the cycle or Cancel to clear the code. Check the home breaker for the dryer — reset fully off then on. Inspect the power cord at the back of the dryer; tighten the three terminal screws after unplugging.

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: producthelp.amana.com.