Frigidaire · Dryer Moderate

E5C — Exhaust thermistor shorted / over temperature

Control reads thermistor resistance too low or sees an over-temperature condition at the exhaust. Often the sensor is shorted, or airflow is severely restricted causing real overheat.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
frigidaire.com ↗

How to fix it

  1. Unplug the dryer.
  2. Clean the lint filter and inspect the full vent run to the outside hood — clear any blockage.
  3. Remove access panel and measure exhaust thermistor resistance; replace if near 0 ohms.
  4. Inspect heater element/relay for welded contacts.
  5. Run a test cycle and verify exhaust temp with a meter probe — should not exceed ~165°F outlet.
  6. Replace main control board if relay sticks closed with no command.

Why it happens

Typical signs: E5C shown on display · Dryer shuts down during cycle · Cabinet/exhaust hotter than normal · Long dry times

  • Clogged lint screen or vent duct Restricted airflow drives real exhaust temp above limit.
  • Shorted exhaust thermistor Sensor failed shorted, reads near 0 ohms.
  • Stuck-closed heating element relay Element runs constantly even when control commands off.
  • Main control board fault Bad input or relay driver.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • Frigidaire dryer vent cleaning kit Common replacement
    Amazon →
  • Frigidaire exhaust thermistor 131908900 Common replacement
    Amazon →

More Frigidaire dryer codes

All Frigidaire codes → All dryer codes →