E5C — Exhaust thermistor shorted / over temperature
Control reads thermistor resistance too low or sees an over-temperature condition at the exhaust. Often the sensor is shorted, or airflow is severely restricted causing real overheat.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- frigidaire.com ↗
How to fix it
- Unplug the dryer.
- Clean the lint filter and inspect the full vent run to the outside hood — clear any blockage.
- Remove access panel and measure exhaust thermistor resistance; replace if near 0 ohms.
- Inspect heater element/relay for welded contacts.
- Run a test cycle and verify exhaust temp with a meter probe — should not exceed ~165°F outlet.
- Replace main control board if relay sticks closed with no command.
Why it happens
Typical signs: E5C shown on display · Dryer shuts down during cycle · Cabinet/exhaust hotter than normal · Long dry times
- Clogged lint screen or vent duct Restricted airflow drives real exhaust temp above limit.
- Shorted exhaust thermistor Sensor failed shorted, reads near 0 ohms.
- Stuck-closed heating element relay Element runs constantly even when control commands off.
- Main control board fault Bad input or relay driver.