Frigidaire · Refrigerator Serious

HI — High Temperature Alarm

Internal compartment temperature has risen above the safe threshold — usually paired with an audible alarm.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
frigidaire.com ↗

How to fix it

  1. Press the Alarm Reset/HI button to silence the alarm.
  2. Check that all doors are fully closed and gaskets seal.
  3. Allow up to 24 hours for temperature to recover with normal load.
  4. If HI returns, verify evaporator fan is running and coil is not iced over.
  5. Check condenser coil is clean.
  6. If temperature does not recover, diagnose cooling system (compressor, sealed system, sensors).

Why it happens

Typical signs: HI on display · Audible beeping · Food warmer than expected · Possibly thawed items in freezer

  • Door left ajar Most common cause — gasket not sealing or door blocked open.
  • Recent power outage Temperature climbed while unplugged.
  • Cooling system fault Fan, compressor, or refrigerant problem keeping temp high.
  • Heavy load just added Lots of warm food added at once.

More Frigidaire refrigerator codes

All Frigidaire codes → All refrigerator codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: frigidaire.com.