OP — Sensor Circuit Open
Open-circuit indication on a temperature sensor input — generic sensor-open fault on some Frigidaire models.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- frigidaire.com ↗
How to fix it
- Unplug refrigerator.
- Identify which compartment displays OP (fresh food side or freezer side).
- Ohm the corresponding thermistor and replace if open.
- Reseat or repair wiring.
- Replace main board if input is dead.
Why it happens
Typical signs: OP shown in temperature display · Cooling control degraded · Possible defrost issues
- Open thermistor Sensor element failed.
- Disconnected sensor Connector unseated.
- Broken wire Conductor severed.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Thermistor sensor Common replacementAmazon →
More Frigidaire refrigerator codes
Frequently asked questions
What does the OP code mean on a Frigidaire refrigerator?
Open-circuit indication on a temperature sensor input — generic sensor-open fault on some Frigidaire models.
What causes the OP code on a Frigidaire refrigerator?
Open thermistor: Sensor element failed. Disconnected sensor: Connector unseated. Broken wire: Conductor severed.
Is it safe to keep using a Frigidaire refrigerator with a OP error?
Yes, with caution. This is rated a moderate-severity fault.
How do I fix OP on a Frigidaire refrigerator?
Unplug refrigerator. Identify which compartment displays OP (fresh food side or freezer side). Ohm the corresponding thermistor and replace if open.
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: frigidaire.com.