E1F — Door lock / door switch failure

The control can't confirm the door is closed and latched. The dryer won't start, or stops mid-cycle when it loses the door-closed signal.

Keep using it?
Yes, with caution
DIY difficulty
Easy
Verified against
texastempmasters.com ↗

How to fix it

  1. Open the door and clean lint from the latch and strike area.
  2. Press the door switch plunger by hand — it should click crisply.
  3. Inspect the door strike for damage; bend it gently flush if needed.
  4. If the switch feels mushy or fails to click, replace it.
  5. Verify the switch harness with a multimeter for continuity when the door is closed.
  6. Run a Timed Dry to confirm the fix.

Why it happens

Typical signs: E1F on display · Won't start with door closed · Stops mid-cycle randomly · Door light stays on

  • Lint or debris around the door strike Buildup keeps the door from sitting flush against the switch plunger.
  • Bent or worn door strike/hinge Sagging door doesn't depress the switch fully.
  • Failed door switch Switch contacts pitted or open.
  • Broken switch harness Wire near the door fatigues from constant flex.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • GE dryer door switch Common replacement
    Amazon →