F2 — Outdoor Coil Sensor (T3) Fault
F2 means the outdoor condenser coil temperature sensor (T3 thermistor) is reading open or shorted.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Hard
- Typical cost
- $15-30
- Verified against
- support.mrcool.com ↗
The fix
MrCool outdoor unit condenser coil temperature sensor
Condenser coil temperature sensor (T3 thermistor) open or shorted
Diagnose first: Same DIY-replaceable sensor family as F1 — inspect the connector before ordering a replacement.
Find this part on Amazon →As an Amazon Associate we earn from qualifying purchases.
How to fix it
- Power-cycle at the breaker: off for five minutes, back on.
- If F2 returns, call an HVAC technician. The coil sensor is attached to the condenser coil inside the outdoor cabinet — panel-open, technician territory.
- What the technician will do: test the T3 sensor against specification and replace it if failed. It is a small part; the visit is mostly access and confirming nothing else drove the reading out of range.
Why it happens
Typical signs: Reduced performance or shutdown · F2 on the display
- Failed T3 coil sensor The condenser coil thermistor has failed.
- Loose connector The T3 plug on the outdoor board is loose.