MrCool Mini-Split F3 — Compressor Discharge Sensor (TP) Fault

MrCool Mini-Split · Error code F3

What F3 Means

F3 means the compressor discharge temperature sensor (TP thermistor) is open, shorted, or reading a dangerously high temperature. The unit protects the compressor by shutting down.

Symptoms

  • Outdoor unit stops
  • Poor heating/cooling
  • F3 on the display

Common Causes

1
Failed discharge thermistor

The TP sensor on the compressor has failed.

2
Low refrigerant charge

A low charge makes the compressor run hot, raising discharge temperature.

How to Fix It

  1. Power off and reseat the TP sensor connector on the outdoor board.
  2. If the unit was recently installed/charged, verify the refrigerant charge — low charge causes high discharge temps.
  3. Replace the sensor if faulty; a persistent high-temp trip needs a technician to check the charge and compressor.