F3 — Compressor Discharge Sensor (TP) Fault

F3 means the compressor discharge temperature sensor (TP thermistor) is open, shorted, or reading a dangerously high temperature. The unit protects the compressor by shutting down.

Keep using it?
Limited use only
DIY difficulty
Hard
Verified against
support.mrcool.com ↗

How to fix it

  1. Power-cycle once at the breaker: off for five minutes, back on. Do not keep repeating this — F3 exists to protect the compressor from running too hot.
  2. Make sure the outdoor unit can breathe: clear debris, vegetation, and anything blocking airflow around it. Poor heat rejection pushes discharge temperature up.
  3. If F3 returns, call an HVAC technician promptly and stop running the system — a genuinely hot compressor is being damaged every time it runs.
  4. What the technician will do: test the TP sensor first (a failed sensor is the cheap outcome), then check refrigerant charge and system pressures if the high reading is real. Low charge is a classic cause of high discharge temperature, and diagnosing it is gauge work.

Why it happens

Typical signs: Outdoor unit stops · Poor heating/cooling · F3 on the display

  • Failed discharge thermistor The TP sensor on the compressor has failed.
  • Low refrigerant charge A low charge makes the compressor run hot, raising discharge temperature.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • Mini-Split Outdoor Sensor Kit Common replacement
    Amazon →

More MrCool mini-split codes

All MrCool codes → All mini-split codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: support.mrcool.com.