E351 — Water Flow Sensor Fault
The flow turbine sensor signal is missing or out of range — the unit cannot reliably measure GPM.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- navieninc.com ↗
How to fix it
- Shut off water supply and close isolation valves.
- Clean the cold-water inlet screen.
- Remove the flow sensor and check the turbine for free rotation; clear debris.
- Reseat the sensor harness at PCB.
- Replace the flow sensor if turbine spins freely but no signal is detected.
- Descale the unit if hard-water deposits are visible.
Why it happens
Typical signs: E351 on display · Unit does not fire on hot demand · Erratic outlet temperature · Burner won't light despite open tap
- Flow sensor turbine jammed by debris Sediment or pipe scale stops the impeller from spinning.
- Failed Hall-effect sensor Sensor electronics no longer outputting a pulse train.
- Loose or corroded sensor harness Intermittent signal to PCB.
- Clogged inlet screen Restricted flow keeps the turbine below activation threshold.
Parts you may need