C80 — / C90 — Vent Blockage Detected
Samsung dryers run a vent check and report C80 (~80% blocked) or C90 (over 90% blocked). It warns the exhaust duct is clogged — an airflow and fire-safety issue.
- Keep using it?
- Limited use only
- DIY difficulty
- Easy
- Verified against
- samsung.com ↗
How to fix it
- Clean the lint filter and the filter housing.
- Disconnect the duct and clean it fully out to the exterior vent with a brush kit.
- Replace crushed flexible duct with rigid/semi-rigid duct; confirm the outside flap opens.
- Run the Vent Check (Smart Check) again to confirm it clears.
Why it happens
Typical signs: Clothes take multiple cycles to dry · Dryer runs hot · C80 or C90 on the display
- Lint-clogged exhaust duct Lint has accumulated in the duct between the dryer and the outside vent.
- Crushed or too-long vent run A kinked or excessively long duct restricts airflow.