E5B — Exhaust thermistor open / under temperature
The control sees the exhaust (outlet) thermistor reading abnormally low resistance or open, suggesting the sensor or its wiring is faulty rather than an actual temperature fault.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- frigidaire.com ↗
How to fix it
- Unplug the dryer before any testing.
- Remove the rear panel (electric) or front toe panel and tip the drum to access the blower housing.
- Locate the exhaust thermistor (small 2-wire sensor on blower outlet).
- Inspect the connector and wires for damage; reseat the plug.
- Measure thermistor resistance at room temperature — should read ~50k ohms (10k–50k depending on model). Open circuit = replace.
- If thermistor is good, check harness continuity from sensor to main control.
- If both are good, replace the main control board.
Why it happens
Typical signs: E5B flashes on display · Dryer stops mid-cycle · Clothes still wet at cycle end · No heat or very low heat
- Open or failed exhaust thermistor Sensor on the blower housing reads out of range (should be roughly 50k ohms at room temperature).
- Broken wire or loose connector to thermistor Harness chafe near the blower housing or unseated 2-pin plug.
- Failed main control board Less common — board input circuit damaged.