E5B Moderate Moderate DIY

Frigidaire Dryer E5B — Exhaust thermistor open / under temperature

Frigidaire Dryer · Error code E5B

What E5B Means

The control sees the exhaust (outlet) thermistor reading abnormally low resistance or open, suggesting the sensor or its wiring is faulty rather than an actual temperature fault.

Symptoms

  • E5B flashes on display
  • Dryer stops mid-cycle
  • Clothes still wet at cycle end
  • No heat or very low heat

Common Causes

1
Open or failed exhaust thermistor

Sensor on the blower housing reads out of range (should be roughly 50k ohms at room temperature).

2
Broken wire or loose connector to thermistor

Harness chafe near the blower housing or unseated 2-pin plug.

3
Failed main control board

Less common — board input circuit damaged.

How to Fix It

  1. Unplug the dryer before any testing.
  2. Remove the rear panel (electric) or front toe panel and tip the drum to access the blower housing.
  3. Locate the exhaust thermistor (small 2-wire sensor on blower outlet).
  4. Inspect the connector and wires for damage; reseat the plug.
  5. Measure thermistor resistance at room temperature — should read ~50k ohms (10k–50k depending on model). Open circuit = replace.
  6. If thermistor is good, check harness continuity from sensor to main control.
  7. If both are good, replace the main control board.