E8 — Drive motor / power supply fault
The control reports a fault on the drive motor or its power supply circuit. The drum won't tumble or starts then stops.
- Keep using it?
- Limited use only
- DIY difficulty
- Hard
- Verified against
- texastempmasters.com ↗
How to fix it
- Unplug the dryer.
- Spin the drum by hand — should rotate freely. Resistance means a seized bearing, belt jam, or blower wheel.
- Remove the belt and try to spin the motor shaft and blower wheel by hand. Stiff = replace the affected part.
- If everything spins freely, test the motor windings for continuity per the tech sheet.
- Reassemble and retest.
- If the motor and mechanical path are good, replace the main control board.
Why it happens
Typical signs: E8 on display · Drum won't turn · Humming with no rotation · Motor starts then trips off
- Seized blower wheel or drum bearing Mechanical load pulls motor amps high; control trips.
- Failed drive motor Open winding or worn brushes/centrifugal switch.
- Broken belt jamming idler Belt tangled around the motor pulley loads the motor.
- Failed main control board Motor relay or sense circuit on the board has failed.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More GE dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: texastempmasters.com.