F22 — Exhaust Thermistor Fault
The control sees an exhaust temperature sensor (thermistor) reading out of range — open or shorted circuit. Drying will be inaccurate or aborted.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- kitchenaid.com ↗
How to fix it
- Unplug the dryer.
- Locate the thermistor on the blower housing (rear).
- Disconnect and measure resistance — should be near 10kΩ at room temperature.
- If out of spec or open/shorted, replace the thermistor.
- Inspect harness for damage; reseat connector and restore power.
Why it happens
Typical signs: F22 on display · Auto cycles end too quickly or run long · Clothes coming out damp or over-dried
- Failed exhaust thermistor Resistance out of spec (should be ~10kΩ at 77°F)
- Loose or corroded thermistor connector Harness plug at the blower housing
- Broken wire to thermistor Chafed or pinched wire in the harness
- Main control board fault ACU input circuit damaged
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Dryer exhaust thermistor Common replacementAmazon →
More KitchenAid dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: kitchenaid.com.