KitchenAid · Dryer Moderate

F22 — Exhaust Thermistor Fault

The control sees an exhaust temperature sensor (thermistor) reading out of range — open or shorted circuit. Drying will be inaccurate or aborted.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
kitchenaid.com ↗

How to fix it

  1. Unplug the dryer.
  2. Locate the thermistor on the blower housing (rear).
  3. Disconnect and measure resistance — should be near 10kΩ at room temperature.
  4. If out of spec or open/shorted, replace the thermistor.
  5. Inspect harness for damage; reseat connector and restore power.

Why it happens

Typical signs: F22 on display · Auto cycles end too quickly or run long · Clothes coming out damp or over-dried

  • Failed exhaust thermistor Resistance out of spec (should be ~10kΩ at 77°F)
  • Loose or corroded thermistor connector Harness plug at the blower housing
  • Broken wire to thermistor Chafed or pinched wire in the harness
  • Main control board fault ACU input circuit damaged

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • Dryer exhaust thermistor Common replacement
    Amazon →

More KitchenAid dryer codes

All KitchenAid codes → All dryer codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: kitchenaid.com.