KitchenAid · Dryer Moderate
F29 — Moisture Sensor Open
The moisture sensor circuit is open — usually a wiring break or disconnected sensor.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- kitchenaid.com ↗
How to fix it
- Unplug the dryer.
- Remove the top and front panel to access the moisture sensor harness.
- Reconnect or repair any broken wires.
- If wires are good, replace the moisture sensor strip assembly.
- Reassemble and test on Auto Dry.
Why it happens
Typical signs: F29 displayed · Cycle aborts on Auto Dry · Sensor cycles will not run
- Disconnected sensor connector Plug came off at the bulkhead
- Broken wire Harness cut or burned through
- Failed sensor bars Internal break in the strip assembly
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Moisture sensor strip assembly Common replacementAmazon →
More KitchenAid dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: kitchenaid.com.