KitchenAid · Dryer Serious

L2 — Low or No Line Voltage (Electric Dryers)

The electric dryer is sensing one leg of the 240V supply missing or weak. The heater will not energize without both legs.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
kitchenaid.com ↗

How to fix it

  1. Reset the breaker fully OFF then ON (both poles).
  2. Unplug the dryer and inspect the terminal block — tighten the cord connections.
  3. Check the power cord for damage or scorching.
  4. Have an electrician verify 240V at the outlet (120V leg-to-neutral, 240V leg-to-leg).
  5. Replace the cord or outlet as needed.

Why it happens

Typical signs: L2 on display · Dryer runs but no heat · Long drying times

  • Tripped half of the double-pole breaker One side tripped while the other holds
  • Loose terminal block connection Power cord screws backed off at the dryer terminal block
  • Damaged power cord Burnt or broken conductor in the cord
  • Faulty outlet Burnt receptacle or loose pigtail

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • 4-prong dryer power cord Common replacement
    Amazon →

More KitchenAid dryer codes

All KitchenAid codes → All dryer codes →