L2 — Low or No Line Voltage (Electric Dryers)
The electric dryer is sensing one leg of the 240V supply missing or weak. The heater will not energize without both legs.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- kitchenaid.com ↗
How to fix it
- Reset the breaker fully OFF then ON (both poles).
- Unplug the dryer and inspect the terminal block — tighten the cord connections.
- Check the power cord for damage or scorching.
- Have an electrician verify 240V at the outlet (120V leg-to-neutral, 240V leg-to-leg).
- Replace the cord or outlet as needed.
Why it happens
Typical signs: L2 on display · Dryer runs but no heat · Long drying times
- Tripped half of the double-pole breaker One side tripped while the other holds
- Loose terminal block connection Power cord screws backed off at the dryer terminal block
- Damaged power cord Burnt or broken conductor in the cord
- Faulty outlet Burnt receptacle or loose pigtail