E05 — Water supply problem (steam models)
E05 indicates the dryer expected water to enter the steam system within a set time and did not detect it. The cycle is paused or aborted because steaming without water can damage the generator.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Easy
- Verified against
- lg.com ↗
How to fix it
- Confirm the water supply valve at the wall is fully open.
- Pull the dryer out and inspect the inlet hose for kinks; straighten or replace.
- Shut off water, disconnect the inlet hose at the dryer, and clean the small inlet screen with a soft brush.
- Reconnect, restore water, and run a Steam cycle.
- If E05 persists, test the water inlet valve solenoid for continuity and replace if open.
Why it happens
Typical signs: E05 on display during a Steam cycle · No steam during steam phase · Standard cycles unaffected
- Household water supply closed Supply valve to the dryer is off.
- Kinked or crushed inlet hose Hose pinched behind the dryer.
- Clogged inlet screen Filter screen at the dryer water inlet plugged with debris.
- Failed water inlet valve Solenoid does not open.
- Low household water pressure Below the spec needed to trip the flow sensor.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More LG dryer codes