nP Serious Moderate DIY

LG Dryer nP — No power detected at heater

LG Dryer · Error code nP

What nP Means

nP indicates the main control sees no current flowing through the heater circuit when it should be energized. On 240V electric models this usually points at a power-supply problem rather than the element itself.

Symptoms

  • nP on display
  • Drum tumbles but stays cold
  • Recently installed or moved
  • Dryer working on a generator or sub-panel

Common Causes

1
Only one 120V leg present

Half of the 240V supply is missing — tripped half of a double-pole breaker, or one leg of the cord disconnected.

2
Tripped breaker

30A double-pole breaker partially or fully tripped.

3
Loose terminal block lug

Cord wire backed out or terminal scorched.

4
Open heating element

Element coil failed open.

5
Open high-limit / thermal fuse

Safety device tripped from prior overheat event.

How to Fix It

  1. Unplug the dryer and shut off the 30A breaker.
  2. Test the outlet with a multimeter: ~240V across the two hots, ~120V from each hot to neutral.
  3. Remove the terminal cover and verify all three or four wires are tight on the block.
  4. If voltage and wiring are good, access the heating element and measure resistance — typically ~10 Ω; infinite means replace.
  5. Test the thermal fuse and high-limit thermostat for continuity; replace any open one and address the airflow restriction that caused the trip.
  6. Reassemble and verify heat returns on a Timed Dry cycle.