LG · Dryer Minor
PF — Power Failure during cycle
PF indicates the dryer lost AC power mid-cycle and resumed when power returned. It is informational, not a hardware fault, but it can mask an intermittent power problem if it recurs often.
- Keep using it?
- Yes — fix when convenient
- DIY difficulty
- Easy
- Verified against
- lg.com ↗
How to fix it
- Press Start/Pause to clear PF and resume.
- If PF returns, unplug the dryer for 60 seconds, then plug back in to factory-reset.
- Check the 30A double-pole breaker in the panel — reset if tripped, replace if it trips repeatedly.
- Inspect the cord and outlet for heat discoloration, scorch marks, or loose lugs and replace any damaged parts.
Why it happens
Typical signs: PF shown after a power blip · Cycle stopped partway through · Display flashing on resume
- Brief utility power outage Grid sag or momentary outage interrupted the cycle.
- Tripped breaker 240V breaker tripped and was reset.
- Loose plug or cord Dryer cord vibrated partially out of the outlet.
- Cord/terminal block damage Heat-damaged terminal causes intermittent dropout.
More LG dryer codes