LG Dryer PS — Power Source / improper voltage or reversed line
LG Dryer · Error code PS
What PS Means
PS indicates the dryer detects an unexpected power source condition — typically the two 120V hot legs of the 240V supply are reversed, neutral and a hot are swapped, or the dryer is being fed from a single 120V leg.
Symptoms
- PS displayed at startup
- Dryer will not start a cycle
- Heater never energizes
- Recently installed or moved unit
Common Causes
L1 and N (or L1/L2) swapped during install.
Three- or four-prong cord installed with the wrong jumper configuration.
Outlet is wired 120V single-phase instead of 240V split-phase.
Loose, scorched, or broken terminal.
How to Fix It
- Unplug the dryer and turn off the breaker before touching the terminal block.
- Remove the terminal cover on the back of the dryer and verify wiring matches the LG installation diagram for a 3-wire or 4-wire cord.
- With a multimeter, confirm the outlet reads ~240V between L1 and L2, ~120V from each hot to neutral.
- Re-tighten any loose lugs and confirm the neutral/ground jumper is correctly configured for your cord type.
- Restore power and verify PS clears; if it returns, have an electrician inspect the branch circuit.
Parts You May Need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
More LG Dryer Codes
Verified against manufacturer documentation: lg.com