PS — Power Source / improper voltage or reversed line

PS indicates the dryer detects an unexpected power source condition — typically the two 120V hot legs of the 240V supply are reversed, neutral and a hot are swapped, or the dryer is being fed from a single 120V leg.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
lg.com ↗

How to fix it

  1. Unplug the dryer and turn off the breaker before touching the terminal block.
  2. Remove the terminal cover on the back of the dryer and verify wiring matches the LG installation diagram for a 3-wire or 4-wire cord.
  3. With a multimeter, confirm the outlet reads ~240V between L1 and L2, ~120V from each hot to neutral.
  4. Re-tighten any loose lugs and confirm the neutral/ground jumper is correctly configured for your cord type.
  5. Restore power and verify PS clears; if it returns, have an electrician inspect the branch circuit.

Why it happens

Typical signs: PS displayed at startup · Dryer will not start a cycle · Heater never energizes · Recently installed or moved unit

  • Reversed white/red wires at the terminal block L1 and N (or L1/L2) swapped during install.
  • Missing neutral or open ground Three- or four-prong cord installed with the wrong jumper configuration.
  • Wrong outlet voltage Outlet is wired 120V single-phase instead of 240V split-phase.
  • Bad cord or terminal block Loose, scorched, or broken terminal.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • 4-prong dryer cord 30A Common replacement
    Amazon →
  • 3-prong dryer cord 30A Common replacement
    Amazon →

More LG dryer codes

All LG codes → All dryer codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: lg.com.