F6E1 — Compressor / Inverter Fault
On variable-speed compressor models, the control detected a fault on the inverter board driving the compressor. Cooling may be lost.
- Keep using it?
- Limited use only
- DIY difficulty
- Hard
- Verified against
- maytag.com ↗
How to fix it
- Unplug the refrigerator before servicing the compressor area.
- Pull the refrigerator out and remove the rear access panel.
- Inspect the inverter board mounted to the compressor for burn marks or swollen components.
- Verify the 3-wire harness from inverter to compressor is fully seated.
- Measure compressor winding resistance per service sheet (typically balanced low ohms).
- Replace the inverter board first; if compressor windings are bad, the compressor itself needs replacement (sealed-system work — call a tech).
- Verify line voltage is 108-132V at the outlet.
Why it happens
Typical signs: F6E1 displayed · Compressor not running · All compartments warming · Inverter board warm or clicking
- Failed inverter board Power electronics on the compressor inverter failed.
- Failed compressor Compressor windings shorted or open.
- Loose compressor harness Three-phase connector to compressor came loose.
- Voltage supply issue Low line voltage or surge damage.