Rinnai · Tankless Water Heater Moderate
02 — Power Interruption / Memory Loss
The unit lost power or experienced a brownout and the control board reset. Often appears after a storm or breaker trip.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Easy
- Verified against
- rinnai.us ↗
How to fix it
- Turn the unit off at the controller and unplug or kill the breaker for 60 seconds.
- Restore power and re-set temperature on the remote.
- Verify the breaker is fully seated and the outlet/whip is tight.
- Check voltage at the unit — should be ~120V AC stable.
- If code returns with no outage, replace the PCB.
Why it happens
Typical signs: Unit not responding to demand · Code 02 on remote/display · Settings reverted to defaults
- Power interruption Brief outage or voltage sag reset the PCB.
- Loose power connection Plug, hardwire, or terminal block not making solid contact.
- Tripped breaker Breaker partially tripped or fluctuating.
- Failing PCB Control board losing memory on its own indicates board failure.
More Rinnai tankless water heater codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: rinnai.us.