Rinnai · Tankless Water Heater Serious

12 — Flame Failure

The unit lit successfully but lost flame signal during operation. Indicates intermittent gas, combustion, or sensing problem.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
rinnai.us ↗

How to fix it

  1. Remove and clean the flame rod with fine emery cloth — do not over-polish.
  2. Verify chassis ground and that the unit is bonded properly.
  3. Have inlet gas pressure measured at high fire (dynamic) — must stay in spec.
  4. Confirm gas line sizing and length are correct per install manual.
  5. Inspect vent terminations for partial blockage.
  6. If flame rod and gas pressure are good, replace the gas valve assembly.

Why it happens

Typical signs: Hot water starts then goes cold · Burner cycles on/off rapidly · Code 12 mid-shower

  • Dirty flame rod Carbon or scale on flame sensor preventing flame detection.
  • Low gas pressure under load Inlet pressure drops below spec when burner ramps up.
  • Undersized gas line Line too small for BTU load over the run length.
  • Restricted air supply Partially blocked intake/exhaust causing unstable combustion.
  • Faulty gas valve modulation Solenoid not metering correctly at high fire.
  • Poor grounding Flame rectification requires good chassis ground.