12 — Flame Failure
The unit lit successfully but lost flame signal during operation. Indicates intermittent gas, combustion, or sensing problem.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- rinnai.us ↗
How to fix it
- Remove and clean the flame rod with fine emery cloth — do not over-polish.
- Verify chassis ground and that the unit is bonded properly.
- Have inlet gas pressure measured at high fire (dynamic) — must stay in spec.
- Confirm gas line sizing and length are correct per install manual.
- Inspect vent terminations for partial blockage.
- If flame rod and gas pressure are good, replace the gas valve assembly.
Why it happens
Typical signs: Hot water starts then goes cold · Burner cycles on/off rapidly · Code 12 mid-shower
- Dirty flame rod Carbon or scale on flame sensor preventing flame detection.
- Low gas pressure under load Inlet pressure drops below spec when burner ramps up.
- Undersized gas line Line too small for BTU load over the run length.
- Restricted air supply Partially blocked intake/exhaust causing unstable combustion.
- Faulty gas valve modulation Solenoid not metering correctly at high fire.
- Poor grounding Flame rectification requires good chassis ground.