Rinnai · Tankless Water Heater Critical

16 — Outgoing Water Over-Temperature

Outlet water temperature exceeded the safety limit. Unit shuts down to prevent scalding and exchanger damage.

Keep using it?
No — service first
DIY difficulty
Moderate
Verified against
rinnai.us ↗

How to fix it

  1. Clean the inlet water filter and confirm full flow.
  2. Descale the heat exchanger with manufacturer-approved solution.
  3. Test outlet thermistor resistance per service manual.
  4. Check for hot/cold crossover at single-handle faucets and the recirc loop check valve.
  5. Verify gas valve modulates — if stuck, replace valve assembly.
  6. Replace outlet thermistor if out of spec.

Why it happens

Typical signs: Hot water briefly very hot then cold · Code 16 after high-demand draw · Scale visible at fixtures

  • Scale in heat exchanger Insulating scale layer causes localized superheat.
  • Low water flow Clogged filter or partly closed valve — heat per unit volume is too high.
  • Faulty outlet thermistor Sensor reading high or unstable.
  • Gas valve stuck open / over-firing Modulating valve failing to throttle.
  • Recirculation crossover Hot/cold crossover causing temperature creep.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

More Rinnai tankless water heater codes

All Rinnai codes → All tankless water heater codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: rinnai.us.