Rinnai · Tankless Water Heater Moderate

03 — Loss of Communication / EZConnect Issue

Communication fault between two units linked with EZConnect/MSA or between the main board and remote.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
rinnai.us ↗

How to fix it

  1. Power down both units at the breaker.
  2. Reseat the EZConnect / MSA communication cables on both ends.
  3. Inspect for rodent damage or pinched wires.
  4. Swap remote wires to isolate which unit is faulting.
  5. If wiring is good, replace the MSA or PCB.

Why it happens

Typical signs: Code 03 with multi-unit setup · One unit fires, other doesn't · Remote dropping out

  • EZConnect cable loose or damaged Communication harness between units unplugged or pinched.
  • MSA controller fault Manifold System Adapter failed.
  • Bad remote wiring MC-91 controller wire shorted or open.
  • PCB communication chip failure Less common; replace board.