10 — Air Supply or Exhaust Blockage
The unit detects insufficient combustion air or restricted venting. Safety lockout to prevent CO production.
- Keep using it?
- Limited use only
- DIY difficulty
- Moderate
- Verified against
- rinnai.us ↗
How to fix it
- Inspect intake and exhaust terminations outside — clear any blockage.
- Remove front cover and check fan blade for debris; spin freely by hand.
- Measure total vent length and elbow count against installation manual.
- Verify slope on horizontal runs (1/4 inch per foot toward unit or drain on condensing models).
- Check for sealed combustion: no other appliances pulling air from the same space.
- Replace fan motor if it doesn't spin smoothly or draws wrong amps.
Why it happens
Typical signs: Unit fires briefly then shuts off · Code 10 during cold weather · Reduced or no hot water
- Blocked intake or exhaust vent Bird nest, snow, ice, leaves, or wasp nest at termination.
- Vent length exceeds spec Too many elbows or runs too long for the model.
- Improper vent termination Concentric cap clogged or intake/exhaust too close together.
- Dirty fan or fan failure Combustion fan can't move required CFM.
- Negative pressure in mechanical room Other appliances starving the unit of air.
- Condensate blocking exhaust (condensing models) Sagging vent holding water.