Rinnai · Tankless Water Heater Moderate

31 — Burner Sensor (Combustion Offset) Fault

Abnormal combustion offset reading. Often a wiring or PCB-side fault on the burner thermistor.

Keep using it?
Yes, with caution
DIY difficulty
Hard
Verified against
media.rinnai.us ↗

How to fix it

  1. Power down and reseat all sensor harnesses at the PCB.
  2. Verify dip-switch settings match installation manual for gas type and model.
  3. Measure burner sensor resistance — compare to spec.
  4. Replace the burner sensor if out of spec.
  5. If sensor and wiring are good, replace the PCB.

Why it happens

Typical signs: Code 31 on power-up or under load · Unit fails to fire or shuts off shortly after firing

  • Faulty burner sensor Thermistor failed or out of spec.
  • Loose wire harness at PCB Connector backed out or corroded.
  • PCB failure Control board can't read sensor.
  • Dip-switch / configuration error Unit set up for wrong gas or model variant.

More Rinnai tankless water heater codes

All Rinnai codes → All tankless water heater codes →

Frequently asked questions

What does the 31 code mean on a Rinnai tankless water heater?

Abnormal combustion offset reading. Often a wiring or PCB-side fault on the burner thermistor.

What causes the 31 code on a Rinnai tankless water heater?

Faulty burner sensor: Thermistor failed or out of spec. Loose wire harness at PCB: Connector backed out or corroded. PCB failure: Control board can't read sensor.

Is it safe to keep using a Rinnai tankless water heater with a 31 error?

Yes, with caution. This is rated a moderate-severity fault.

How do I fix 31 on a Rinnai tankless water heater?

Power down and reseat all sensor harnesses at the PCB. Verify dip-switch settings match installation manual for gas type and model. Measure burner sensor resistance — compare to spec.

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: media.rinnai.us.