31 Moderate Hard — consider a tech

Rinnai Tankless Water Heater 31 — Burner Sensor (Combustion Offset) Fault

Rinnai Tankless Water Heater · Error code 31

What 31 Means

Abnormal combustion offset reading. Often a wiring or PCB-side fault on the burner thermistor.

Symptoms

  • Code 31 on power-up or under load
  • Unit fails to fire or shuts off shortly after firing

Common Causes

1
Faulty burner sensor

Thermistor failed or out of spec.

2
Loose wire harness at PCB

Connector backed out or corroded.

3
PCB failure

Control board can't read sensor.

4
Dip-switch / configuration error

Unit set up for wrong gas or model variant.

How to Fix It

  1. Power down and reseat all sensor harnesses at the PCB.
  2. Verify dip-switch settings match installation manual for gas type and model.
  3. Measure burner sensor resistance — compare to spec.
  4. Replace the burner sensor if out of spec.
  5. If sensor and wiring are good, replace the PCB.

More Rinnai Tankless Water Heater Codes

All Rinnai codes → All tankless water heater codes →

Verified against manufacturer documentation: rinnai.us

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician.