Rinnai · Tankless Water Heater Moderate
33 — Heat Exchanger Thermistor Fault
The heat exchanger temperature sensor is open, shorted, or out of range.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- rinnai.us ↗
How to fix it
- Power off unit.
- Reseat sensor connector and inspect for corrosion.
- Measure thermistor resistance vs. service manual chart.
- Replace thermistor if reading is out of spec.
- If sensor and wiring check OK, replace the PCB.
Why it happens
Typical signs: Code 33 on demand · Unit shuts down quickly after firing
- Failed heat exchanger thermistor Sensor open/short.
- Connector loose or corroded Common in humid mechanical rooms.
- Wire damage Harness chafed against exchanger.
- PCB input issue Less common.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Heat exchanger thermistor Common replacementAmazon →
More Rinnai tankless water heater codes