Rinnai · Tankless Water Heater Moderate

71 — Gas Solenoid Drive Circuit Fault

The PCB has detected an abnormal condition in the solenoid drive circuit.

Keep using it?
Yes, with caution
DIY difficulty
Hard
Verified against
media.rinnai.us ↗

How to fix it

  1. Power down and inspect gas valve wiring for damage or shorts to chassis.
  2. Measure solenoid coil resistance — replace gas valve if out of spec.
  3. If wiring and valve are good, replace the PCB.

Why it happens

Typical signs: Code 71 on power up or ignition · No burner operation

  • PCB drive circuit failure Board can't actuate solenoid correctly.
  • Shorted solenoid coil Pulling abnormal current.
  • Wiring short Harness shorted to chassis.

More Rinnai tankless water heater codes

All Rinnai codes → All tankless water heater codes →

Frequently asked questions

What does the 71 code mean on a Rinnai tankless water heater?

The PCB has detected an abnormal condition in the solenoid drive circuit.

What causes the 71 code on a Rinnai tankless water heater?

PCB drive circuit failure: Board can't actuate solenoid correctly. Shorted solenoid coil: Pulling abnormal current. Wiring short: Harness shorted to chassis.

Is it safe to keep using a Rinnai tankless water heater with a 71 error?

Yes, with caution. This is rated a moderate-severity fault.

How do I fix 71 on a Rinnai tankless water heater?

Power down and inspect gas valve wiring for damage or shorts to chassis. Measure solenoid coil resistance — replace gas valve if out of spec. If wiring and valve are good, replace the PCB.