Rinnai · Tankless Water Heater Critical

90 — Combustion Abnormality

The unit detected abnormal combustion — usually incomplete combustion or wrong flame characteristics. Safety lockout.

Keep using it?
No — service first
DIY difficulty
Hard
Verified against
rinnai.us ↗

How to fix it

  1. STOP using unit and call a qualified gas tech — this is a combustion safety code.
  2. Verify gas type matches unit dataplate.
  3. Verify dip switches for gas and altitude.
  4. Inspect intake and exhaust for blockage; clear as needed.
  5. Have inlet gas pressure measured static and dynamic.
  6. Inspect burner and heat exchanger for soot; clean or replace as required.
  7. Replace fan motor if RPM is out of spec.

Why it happens

Typical signs: Code 90 after running · Yellow flame or sooting visible · Sometimes accompanied by burning smell

  • Restricted vent or intake Partial blockage starving combustion.
  • Incorrect gas type / orifice Unit set up for NG running on LP or vice versa.
  • Wrong gas pressure Inlet pressure too high or too low.
  • Heat exchanger fouling / sooting Soot blocking combustion path.
  • Failed combustion fan Wrong air/fuel ratio.
  • Dip-switch / dial set wrong Wrong altitude or gas type setting.

More Rinnai tankless water heater codes

All Rinnai codes → All tankless water heater codes →

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: rinnai.us.