Rinnai · Tankless Water Heater Critical
90 — Combustion Abnormality
The unit detected abnormal combustion — usually incomplete combustion or wrong flame characteristics. Safety lockout.
- Keep using it?
- No — service first
- DIY difficulty
- Hard
- Verified against
- rinnai.us ↗
How to fix it
- STOP using unit and call a qualified gas tech — this is a combustion safety code.
- Verify gas type matches unit dataplate.
- Verify dip switches for gas and altitude.
- Inspect intake and exhaust for blockage; clear as needed.
- Have inlet gas pressure measured static and dynamic.
- Inspect burner and heat exchanger for soot; clean or replace as required.
- Replace fan motor if RPM is out of spec.
Why it happens
Typical signs: Code 90 after running · Yellow flame or sooting visible · Sometimes accompanied by burning smell
- Restricted vent or intake Partial blockage starving combustion.
- Incorrect gas type / orifice Unit set up for NG running on LP or vice versa.
- Wrong gas pressure Inlet pressure too high or too low.
- Heat exchanger fouling / sooting Soot blocking combustion path.
- Failed combustion fan Wrong air/fuel ratio.
- Dip-switch / dial set wrong Wrong altitude or gas type setting.
More Rinnai tankless water heater codes