Rinnai Tankless Water Heater 90 — Combustion Abnormality
Rinnai Tankless Water Heater · Error code 90
What 90 Means
The unit detected abnormal combustion — usually incomplete combustion or wrong flame characteristics. Safety lockout.
Symptoms
- Code 90 after running
- Yellow flame or sooting visible
- Sometimes accompanied by burning smell
Common Causes
Partial blockage starving combustion.
Unit set up for NG running on LP or vice versa.
Inlet pressure too high or too low.
Soot blocking combustion path.
Wrong air/fuel ratio.
Wrong altitude or gas type setting.
How to Fix It
- STOP using unit and call a qualified gas tech — this is a combustion safety code.
- Verify gas type matches unit dataplate.
- Verify dip switches for gas and altitude.
- Inspect intake and exhaust for blockage; clear as needed.
- Have inlet gas pressure measured static and dynamic.
- Inspect burner and heat exchanger for soot; clean or replace as required.
- Replace fan motor if RPM is out of spec.
More Rinnai Tankless Water Heater Codes
Verified against manufacturer documentation: rinnai.us
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician.