Maytag · Dryer Moderate
E2 — Thermistor Shorted
The thermistor circuit reads as shorted (very low resistance). The control disables heat for safety.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Moderate
- Verified against
- maytag.com ↗
How to fix it
- Unplug the dryer.
- Disconnect the thermistor and measure resistance — a near-zero reading means a shorted sensor.
- Replace thermistor if shorted.
- If thermistor reads correctly, inspect the harness for damage where wires pass through metal panels.
- Repair any damaged insulation with proper splices and loom.
- Test with a heated cycle to confirm.
Why it happens
Typical signs: E2 on display · No heat · Cycle terminates early · Drum still turns
- Shorted thermistor Internal failure shorting the element.
- Pinched wire grounded to chassis Wire chafed against sheet metal.
- Water/condensation across sensor terminals From damp environment or leak.
- Failed control board input Rare.
Parts you may need
If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.
- Maytag dryer thermistor Common replacementAmazon →
More Maytag dryer codes
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: maytag.com.