Maytag Dryer E2 — Thermistor Shorted
Maytag Dryer · Error code E2
What E2 Means
The thermistor circuit reads as shorted (very low resistance). The control disables heat for safety.
Symptoms
- E2 on display
- No heat
- Cycle terminates early
- Drum still turns
Common Causes
Internal failure shorting the element.
Wire chafed against sheet metal.
From damp environment or leak.
Rare.
How to Fix It
- Unplug the dryer.
- Disconnect the thermistor and measure resistance — a near-zero reading means a shorted sensor.
- Replace thermistor if shorted.
- If thermistor reads correctly, inspect the harness for damage where wires pass through metal panels.
- Repair any damaged insulation with proper splices and loom.
- Test with a heated cycle to confirm.