Maytag · Dryer Moderate

E2 — Thermistor Shorted

The thermistor circuit reads as shorted (very low resistance). The control disables heat for safety.

Keep using it?
Yes, with caution
DIY difficulty
Moderate
Verified against
maytag.com ↗

How to fix it

  1. Unplug the dryer.
  2. Disconnect the thermistor and measure resistance — a near-zero reading means a shorted sensor.
  3. Replace thermistor if shorted.
  4. If thermistor reads correctly, inspect the harness for damage where wires pass through metal panels.
  5. Repair any damaged insulation with proper splices and loom.
  6. Test with a heated cycle to confirm.

Why it happens

Typical signs: E2 on display · No heat · Cycle terminates early · Drum still turns

  • Shorted thermistor Internal failure shorting the element.
  • Pinched wire grounded to chassis Wire chafed against sheet metal.
  • Water/condensation across sensor terminals From damp environment or leak.
  • Failed control board input Rare.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

  • Maytag dryer thermistor Common replacement
    Amazon →

More Maytag dryer codes

All Maytag codes → All dryer codes →