F02 — Keypad / User Interface Stuck Key
The control detected a button on the user interface that has been pressed for more than ~1 minute, or sees a shorted key. The dryer will not respond to commands.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Easy
- Verified against
- maytag.com ↗
How to fix it
- Unplug the dryer for 1 minute and plug back in.
- Press each button individually to identify a sticky or unresponsive one.
- Clean the console face with a slightly damp cloth (never spray cleaner on it).
- If a key is physically stuck, replace the keypad/membrane assembly.
- If all keys feel normal but the code persists, replace the user interface board.
- Verify operation with a test cycle.
Why it happens
Typical signs: F02 on display · Buttons not responding correctly · Dryer beeps repeatedly · Cycle won't start
- Stuck or shorted membrane button Most common — the touch panel membrane has a key shorted closed.
- Spilled liquid or debris on console Sticky residue can hold a button down.
- Failed user interface board Less common — the UI board itself has failed.
- Loose ribbon cable Connection between keypad and UI board is loose.